Please review these scenarios to determine how F3800 Plus's output ports can be used.
Condition 1: No AC input power is connected.
Usable AC Output Ports:
• TT-30R (120V~25A)
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 2: When a 120V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase. Bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms.
Generator to F3800 Plus: 50 ms.
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 3: When a 240V generator is connected; not plugged into a 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W.
• L14-30R (120/240V~25A): Output available with a bypass limit of up to 6,000W.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 4: No generator connection; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available. No UPS. Bypass limit of up to 1,440W.
• NEMA 5-20R (3 Leftmost Ports, UPS): Output available with bypass limit of up to 1,440W.
Switching Time: 20 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Rightmost Ports)
Condition 5: Connected to 120V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available when connected to the L1 phase wth a bypass limit of up to 3,000W. No output when connected to the L2 phase.
Switching Time:
F3800 Plus to Generator: 30 ms
Generator to F3800 Plus: 50 ms
Non-Usable AC Output Ports:
• L14-30R (120/240V~25A)
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)
Condition 6: Connected to 240V generator; plugged into 120V wall outlet.
Usable AC Output Ports:
• TT-30R (120V~25A): Output available with a bypass limit of up to 3,000W. If the generator stops outputting, please see Condition 4 above.
• L14-30R (120/240V~25A): Output available with a bypass limit of 6,000W max. If the generator stops outputting, please see Condition 4 above.
Non-Usable AC Output Ports:
• NEMA 5-20R (3 Leftmost Ports, UPS)
• NEMA 5-20R (3 Rightmost Ports)